 System balancing
The system balancing service in real time is used for correcting energy deviations from the values specified in contractual schedules of market participants. To correct system imbalance HEP-OPS ensures balancing energy. The settlement for balancing energy is carried out according to Rules on Balancing the Electric Power System
Explanation: Uniform load profile diagram is determined as a weighted relative load share of each hour in the monthly system load which represents basis for planned and reached hourly load distribution on grounds of known monthly values for all customer categories that do not have the possibility of measuring and saving hourly values of electricity consumption.
The procedure of determining load profile diagram of hourly system load is made in the Microsoft Excel „UNIFORM_LOAD_PROFILE_DIAGRAM_2010.xls“ containing three Excel sheets.
- MONTHLY ENERGY
- HOURLY SCHEDULE
- COEFFICIENTS
For data entry, user uses only MONTHLY ENERGY sheet while in the other two sheets such changes are not allowed.
When on the MONTHLY ENERGY sheet, monthly amount of energy is entered (agreed or reached) in kWh, on the HOURLY SCHEDULE sheet are displayed calculated hourly load values in MWh/h allocated by days of the month and hours of the day. On the HOURLY SCHEDULE sheet of the load values calculated for 24 hours of the particular day represent load profile diagram of the hourly system load for that day.
On the COEFFICIENTS sheet are defined relative shares of the system load for each hour of the calendar year.
Note: All forms in English are non-binding unofficial translations (In case of discrepancies between Croatian text and
English text, the Croatian text shall prevail)
|